WEB Catalog

Product Information »  WEB Catalog  » Process Valves  » 2/3 Port Solenoid Valves/Air Operated Valves

2/3 Port Solenoid Valves/Air Operated Valves

Direct Operated/Pilot Operated 2-Port Solenoid Valve JSX/JSX□

    · A pilot operated steam type (JSXP series) has been added. New
    · Improved environmental resistance due to the stainless steel coil cover
     [IP67 enclosure/NEMA4X∗] ∗ IP65 for models with a DIN terminal
    ·Space saving
     Compact: Valve volume reduced by 25%*, Lightweight: Weight reduced
     by 30%*
     * Compared with the existing model
    ·Energy saving
     Coil force: 10% increase*, Power consumption: 14% reduction*
     * Compared with the existing model
    ·360° lead wire insertion and removal is possible.
    ·Improved weather resistance in outdoor environments
SeriesTypeValve typePort sizeOrifice diameter (mmø)
JSXDirect operatedN.C.1/8, 1/4, 3/81.6 to 7.1
JSX□□UDirect operated high flow/ power saving typeN.C.1/8, 1/4, 3/82.4 to 7.1
JSX□□VDirect operated vacuum typeN.C.1/8, 1/4, 3/81.6 to 7.1
JSX□□HDirect operated high pressure typeN.C.1/4, 3/83.2
JSX□□SDirect operated steam typeN.C.1/4, 3/81.6,7.1
JSXMDirect operated modular mounting typeN.C.1/8,1/4,3/8,1/23.2,4
JSXDPilot operatedN.C.1/4,3/8,1/2,3/4,1,
1 1/4,1 1/2,2,32A,40A,50A
10 to 50
JSXPSteam typeN.C.3/8,1/2,3/4,1, 1 1/4,
1 1/2,2,32A,40A,50A
15 to 50
JSXZZero differential pressure type pilot operatedN.C.1/4,3/8,1/2,3/8,1/2,3/4,110 to 25

Features

Improved environmental resistance due to the stainless steel coil cover [IP67 enclosure/NEMA4X]

Series Variations

Space saving
Compact: Valve volume reduced by 25% (Compared with the existing model),
Lightweight: Weight reduced by 30% (Compared with the existing model)

Full-wave rectifier type (AC specification: Insulation type Class B)

  • ・Improved durability

     Extended service life due to the special construction
    (Compared with the existing shading coil)


    ・Reduced buzzing noise

     Due to being rectified to DC by the full-wave rectifier


    ・Reduced apparent power

     * Class B, N.C. valve (Compared with the existing model)

     9.5 VA → 8 VA (JSX20/JSXD60, 70 Series)
     12 VA → 9.5 VA(JSX30/JSXD80, 90 Series)

  • ・Improved OFF response

     Specially constructed to improve the OFF response when operated with high viscosity fluids such as oil


    ・Low-noise construction

     Specially constructed to reduce metal noise during operation




Improved weather resistance in outdoor environments

Full-wave rectifier type (AC specification: Insulation type Class B)