Electronic Pressure Switches/Sensors (Self-contained Type)
3-Color Display Digital Gap Checker ISA3
![](https://www.smcworld.com/upfiles/etc/series/en-jp/img1-ISA3.jpg)
-
・Made-to-order options have been added. [New]
・A type compatible with control units
without a 2-port solenoid valve
・A cable in-line entry type
・Check at a glance to see if a workpiece is placed or not.
・The clearance distance between the detection surface and the workpiece can be found intuitively.
・Simple setting: Change the settings while checking the displayed value.
・Energy saving: Air consumption reduced by 60%
・Improved drainage resistance: 10 times or more
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Rated distance range | Piping specifications: Supply side | Piping specifications: Detection side |
---|---|---|---|
ISA3-F | 0.01 to 0.03 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 |
ISA3-G | 0.02 to 0.15 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 |
ISA3-H | 0.05 to 0.30 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 |
Features
The 2-Screen, 3-Color Digital Display
Check at a glance if the workpiece is placed or not. The clearance distance between the detection surface and the workpiece can be found intuitively.
![](/assets/newproducts/en-jp/isa3/images/01.jpg)
3 Step Setting (Switch Point Change Mode)
Simple setting of the switch point value (point at which the clearance reaches the switch point value)
![](/assets/newproducts/en-jp/isa3/images/02.jpg)
The seating condition can be checked at a glance. The sub screen can display 1 of 6 display options.
![](/assets/newproducts/en-jp/isa3/images/03.jpg)
Improved Environmental Resistance
Easier maintenance
![](/assets/newproducts/en-jp/isa3/images/04.jpg)
Measures against drainage
Drainage resistance:increased by 10 times or more
* Based on SMC’s specific testing conditions (Oil proof test)
* Compared with the ISA2
Withstand pressure increased by Max.:600 kPa(3 times*1 compared with the ISA2)
*1 Compared with the ISA2 with a 0.2 MPa pressure gauge
High-pressure flushing
* The switch output will be OFF during flushing.
Noise reduction, Energy saving, Measures against clogging
![](/assets/newproducts/en-jp/isa3/images/05.jpg)
2 Outputs Type
1. Outlet pressure, 2. Gap size, or 3. Supply pressure can be selected for OUT2.
![](/assets/newproducts/en-jp/isa3/images/06.jpg)
![](/assets/newproducts/en-jp/isa3/images/07-1.jpg)
Compact & Lightweight
![](/assets/newproducts/en-jp/isa3/images/08.jpg)
Space Saving & Reduced Wiring Labor (Centralized Lead Wire)
![](/assets/newproducts/en-jp/isa3/images/09.jpg)
Keylock Function
![](/assets/newproducts/en-jp/isa3/images/10.jpg)
Mounting
![](/assets/newproducts/en-jp/isa3/images/11.jpg)
Piping Variations
![](/assets/newproducts/en-jp/isa3/images/12.jpg)
Manifold
![](/assets/newproducts/en-jp/isa3/images/13.jpg)
Application Examples
Confirmation of the reference plane for the press fitting of shafts
![](/assets/newproducts/en-jp/isa3/images/14.jpg)
Confirmation of close contact with the reference plane for machining
![](/assets/newproducts/en-jp/isa3/images/15.jpg)
Confirmation of close contact with the workpiece for machining
![](/assets/newproducts/en-jp/isa3/images/16.jpg)
Main Functions
Display OFF mode
Display OFF mode can be selected. The display can be turned OFF to reduce power consumption.
![](/assets/newproducts/en-jp/isa3/images/17.jpg)
Display color
The color of the main display can be set to change depending upon the output activity. The display color change makes visual identification of the output ON/OFF easier.
![](/assets/newproducts/en-jp/isa3/images/18.jpg)
Unit conversion
The pressure unit displayed on the sub screen can be changed.
![](/assets/newproducts/en-jp/isa3/images/19.jpg)
Security code
When the security code is activated, the code needs to be entered before the product can be operated.
![](/assets/newproducts/en-jp/isa3/images/20.jpg)
Displayed value compensation
The displayed value can be corrected within ±20% R.D. of the displayed value at the time of shipment.
Forced output
The output can be fixed to an ON/OFF state when starting the system or during maintenance. This enables the confirmation of the wiring and prevents system errors due to unexpected output.
Zero-clear of pressure value